HOME ABOUT US OUR SERVICES DESIGN CAPABILITIES PRODUCT OUR LAB CONTACT US
Charger 1000W
12V, 24V, 36V ,48V, 60V
Charger 1500
12V, 24V, 36V, 48V, 60V
Charger 2000
12V, 24V, 36V, 48V, 60V
Charger 3000W
12V, 24V, 36V, 48V, 60V
Charger 6000W (3 Phase) 12V, 24V, 36V, 48V, 60V
 
 
Home Product

CHARGER 1000W 12V/24V/36V/48V/60V

  Features

·         Controlled by microprocessor

·         Programmable Volt and Current

·         Universal AC input / Full range

·         Built-in active PFC function PF>0.95

·         Protection: Reverse Polarity / Short circuit / Over voltage / Over temperature

·         Charger for lead-acid batteries

·         3 color LED loading indicator

·         Battery Voltage & Charging current display

·         Temperature compensation function

·         Battery UV protection, soft start

 

Specifications
Model
Minnuut 1000-12
Minnuut 1000-24
Minnuut 1000-48
Output
Boost charge voltage
14.4V
28.8V
57.6V
Float charge voltage
13.6V
27.2V
54.4V
Output Current
69.4A
34.7A
17.3A
Recommended Battery Capacity (AMP Hours)
(200 ~ 600)Ah
(120 ~ 350)Ah
(60 ~ 175)Ah
Battery Type
Opened and Sealed Lead Acid
Input
Voltage Range
90 ~ 264VAC 127 ~ 370VDC
Frequency Range
47 ~ 63 Hz
Efficiency (Typical)
85%
87%
88%
Power Factor
0.95@230VAC 0.98@115VAC at full load
AC current (Typical)
12A@115VAC 5.2A@230VAC
In Rush Current (Typical)
25A@115VAC 50A@230VAC
Leakage Current
<3.5mA@240VAC
Protection
Over Voltage
16 ~ 18V
32 ~ 35V
64.5 ~ 69.5V
Protection Type: Shutdown O/P Voltage, Re-Power on recovery
Over Temperature
Protection Type: Shutdown O/P Voltage, Recovers after Temperature goes down
Short Circuit
Protection Type: Internal circuit protection system
Reverse Polarity
Protection Type: Internal circuit protection system
Function
Remote Control
Open: Normal Operation Closed: Stops Charging
Enviroment
Working Temp.
-20 ~ +60°C
Working Humidity
20 ~ 90% RH Non-condensing
Storage Temp. Humidity
-40 ~ +85°C, 10 ~ 95% RH
Temp. Coefficient
±0.05% (0 ~ 50°C) 
Vibration
10 ~ 500Hz, 2G 10min./cycle, 60min., each along X, Y and Z axes
Safety & EMC
Withstand Voltage
I/P-O/P; 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation Resistance
I/P-O/P, I/P-FG, O/P-FG:100MΩ/500VDC 25°C 70%RH
EMI Conduction & Radiation
Compliance to EN55022 (CISPR22)
Harmonic Current
Compliance to EN61000-3-2,-3
EMS immunity
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light Industry level, criteria A
Others
MBTF
250,000 HRS Bellcore
Dimension
TBA

Packing